Jandy A0580905 SHPF and SHPM Pump 2 HP Impeller Replacement Kit| R0807200

$59.99
In stock
SKU
R0807200
- +
Ask a Question

Ask a Question

Jandy A0580905 SHPF and SHPM Pump 2 HP Impeller Replacement Kit| R0807200

SKU#: R0807200

R0807200 Jandy 2HP A0580905  Impeller with Screw and Backplate O-Ring for Pro Series SHPF/SHPM Pumps

Write a Review

Jandy A0580905 SHPF and SHPM Pump 2 HP Impeller Replacement Kit| R0807200

Jandy A0580905 SHPF and SHPM Pump 2 HP Impeller Replacement Kit| R0807200

SKU# R0807200

Manufacturer: Jandy

Price:
$59.99
Rating
$59.99

Ask a Question
Jandy A0580905 SHPF and SHPM Pump 2 HP Impeller Replacement Kit| R0807200 Jandy A0580905 SHPF and SHPM Pump 2 HP Impeller Replacement Kit| R0807200 Jandy A0580905 SHPF and SHPM Pump 2 HP Impeller Replacement Kit| R0807200 Jandy A0580905 SHPF and SHPM Pump 2 HP Impeller Replacement Kit| R0807200 Jandy A0580905 SHPF and SHPM Pump 2 HP Impeller Replacement Kit| R0807200 Jandy A0580905 SHPF and SHPM Pump 2 HP Impeller Replacement Kit| R0807200 Jandy A0580905 SHPF and SHPM Pump 2 HP Impeller Replacement Kit| R0807200
Jandy A0580905 SHPF and SHPM Pump 2 HP Impeller Replacement Kit| R0807200
  • Product Details

    About this product

    Description

    Zodiac Pool Systems Inc, Jandy, Shp- Stealth/ Php-Plushhp, Impeller Kit, Horsepower: 2, For Use With:Vs Plushp Series Pump (Mfg. 2014–Present) Vsphp270, Epump(TM) + Svrs Variable-Speed Pump Jep2.0Svrs, Epump(TM) Variable Speed Pump Jep1.5, Jep2.0, Vsshp22

    Highlights

    Features

    Brand Information

    Build the perfect pool environment with Jandy professional-grade swimming pool equipment. With a full line of pumps, filters, heaters, lights, valves, water sanitizers, and the automation solutions to control it all, Jandy has the complete equipment package for any swimming pool or spa.

    Visit Manufacturers Website
  • Specifications

    Impeller/Diffuser and Hardware

    Replacement

     

    1. Refer to Figures 2a and 2b and the associated parts list to identify the parts included in each replacement kit.

    Figure 2a. Impeller and Diffuser Replacement Kits

    Figure 2b. Impeller and Diffuser Replacement Kits

     

    1. Using a No. 1 Phillips* screwdriver, remove the two (2) screws attaching the diffuser to the backplate. Carefully remove the diffuser from the backplate. See Figure 3.

    Figure 3. Impeller and Diffuser Assembly



    1. If necessary, remove any debris from the inlet and outlet of the impeller.

    NOTE Disregard step 4 if your motor is a Variable Speed

    Model.

     

    1. Remove the motor shaft cover on the back of the motor by twisting the hex-head screw with an adjustable wrench. The motor shaft will be exposed.

    NOTE If the Impeller is not being replaced, please skip to

    Step 9.

     

    1. Hold the exposed motor shaft with a ½' crescent wrench (5/16" allen wrench for Variable Speed Models) while removing the impeller center screw using a No. 2 Phillips screwdriver.

    NOTE The impeller center screw is a left-hand threaded

    screw. Therefore, turn the screw clockwise to loosen it.

    1. The impellor needs to be threaded off of the shaft (normal right-handed thread pitch) and the mechanical seal needs to be replaced.

    NOTE An impellor wrench may be required to break the

    impellor lose.

    1. While holding the motor shaft with a wrench, thread the new impeller onto the motor shaft.

    Hand-tighten the impeller until it is secure.

    1. Using a No. 2 Phillips screwdriver, tighten the impeller's center screw into the center of the impeller. Do not over-tighten. Spin the impeller by hand after installing it, confirming that it will spin freely, without binding.

    NOTE The impeller's center screw is a left-hand threaded

    screw. Therefore, turn the screw counter-clockwise to tighten it.

    1. Replace the motor shaft cover by inserting the cover tabs into the slots and rotating the cover 90° clockwise. (Disregard this step for variable speed pumps.)
    2. Install the new diffuser over the impeller using care to insert the alignment pins into the correct holes. The molded-in arrow must align with the molded-in arrow on the backplate. See Figure 3.
    3. Install the two (2) Phillips-head screws and washers. Tighten the screws to draw the diffuser against the backplate. For 5.0HP, SWF models only, use additional lock washers. See Figure 3.

    NOTE Rotate the motor shaft by using the appropriate

    wrench, ensuring that the motor will turn freely after the installation of the diffuser. If the components are not aligned correctly, you will hear the impeller scraping on the diffuser.

    1. Make sure the diffuser o-rings, o-ring grooves, and o-ring seal areas are clean and free of debris, which could cause a leak. If grease is used to retain the o-rings, it must be silicone based. Do not use petroleum-based grease, because it will destroy the o-rings.
    2. If you are not installing another replacement kit, skip to Section 7, Pump Assembly, to reassemble the pump.
    1. Backplate, Hardware and Mechanical Seal Replacement

    Refer to  Figure 4  and the associated parts list to identify the parts included in each replacement kit

    1. Figure 4 Backplate, Hardware, and Seal Replacement Kits

      The impellor needs to be threaded off of the shaft (normal right-handed thread pitch) and the mechanical seal needs to be replaced. While holding the motor shaft with a wrench, thread the new impeller onto the motor shaft. Using a No. 2 Phillips screwdriver, tighten the impeller's center screw into the center of the impeller. Do not over-tighten. Spin the impeller by hand after installing it, confirming that it will spin freely, without binding. Replace the motor shaft cover by inserting the cover tabs into the slots and rotating the cover 90° clockwise. (Disregard this step for variable speed pumps.)
    2. 1.Disassemble Backplate and Impeller

      Using a No. 1 Phillips screwdriver, remove the two (2) screws attaching the diffuser to the backplate. Carefully remove the diffuser from the backplate and remove any debris from the inlet and outlet of the impeller.

      1. Remove the motor shaft cover on the back of the motor by twisting the hex-head screw 90°

      with a crescent wrench. The motor shaft will be exposed.

      NOTE Disregard step 2 if your motor is a Variable Speed

      model.

      1. Hold the exposed motor shaft with the wrench while removing the impeller center screw using a No. 2 Phillips screwdriver.

      NOTE The impeller screw is a left-hand threaded screw.

      Therefore, turn the screw clockwise to loosen it.

      1. Hold the motor shaft with the wrench while unscrewing the impeller from the motor shaft with your hand.

      NOTE The impeller is a right-hand thread. Therefore, turn it

      counter-clockwise to unscrew it.

      1. Remove the impeller from the backplate and motor shaft
    3.  